Company Profile

Product Description
CHT Series Automatic Image Measuring Instrument
Simple, stable and efficient measurement
Product Description
CHT series fully automatic image measuring instruments cover different ranges and adopt marble body machine, precision servo control system and optical motorized zoom lens to realize high precision measurement.CHT series fully automatic image measuring instruments are powerful and can realize precision measurement of surface dimensions, contours, angles and positions, and form and position tolerances of all kinds of complex parts.
CHT series automatic imaging instrument can be used in machinery, electronics, mold, injection molding, hardware, rubber, low-voltage electrical appliances, magnetic materials, precision stamping, connectors, connectors, terminals, cell phones, home appliances, printed circuit boards, medical equipment, clocks and watches, cutting tools, metrology testing and other fields.
Our Advantages
Feature-rich software with automatic report generation
Completely independent measurement software with intellectual property rights. Provide up to 80 kinds of extraction and analysis tools such as feature extraction, auxiliary construction, intelligent labeling, shape and position tolerance, and special application. Automatically output SPC analysis report and support remote data docking.
measurement function
1. Measurement tools: scanning to extract edge points, multi-segment extraction of edge points, circular extraction of edge points, ellipse extraction, box selection to extract contour lines, focus point, nearest point, etc.
2. Measurable geometric quantities: points, lines, circles (center coordinates, radius, diameter), arcs, centers, angles, distances, line widths, holes, hole diameters, number of holes, hole-to-hole distance, hole-to-edge distance, distance from the center of the arc to the hole, distance from the center of the arc to the edge, distance from the arc high point to the arc high point, the intersection to the intersection, and so on.
3. Construct features: intersection, center point, extreme point, endpoints, two-point line, parallel lines, perpendicular lines, tangent lines, bisectors, center lines, line fusion, radius drawing circles, three-line tangent circles, two-line radius tangent circles, etc.
4. Form and position tolerance: straightness, roundness, contour, position, parallelism, symmetry, perpendicularity, concentricity, and other form and positional tolerance assessment.
5. Coordinate system: instrument coordinate system, point line, two points X, two lines and other workpiece coordinate system; image alignment coordinate system; can be translated, rotated, manually adjusted coordinate system
6. Quick tools: R angle, horizontal pitch, circumferential pitch, screen, slot, contour comparison, springs, O-rings and other special tools for quick measurement.
7. Support tolerance batch setting, scale level division, color customization management.
Simple operation, easy and hassle-free
Anyone can get started quickly and without complex training
1.New Template
Save the template by checking each measurement position of the part to be measured.
2.Placement of workpieces
Positioning the workpiece on the measuring platform
3.batch measurement
Full computer-operated software batch testing
Flexible shooting and precise calculations
Support surface light, transmitted light, coaxial light segment programming control, automatic identification of the measurement site, each time to obtain a uniform and stable measurement results
Wide range of accessories and multiple composite measurements
-Supports touch probes and optical probes for height and flatness measurement, realizing 2.5D spatial measurement.
-Supports external inputs such as calipers and altimeters, centralized data management, and label printers.
Automatic measurements, faster batches
The program matches the coordinate system of the workpiece, automatically executes the measurement process, supports the import of CAD drawings and Gerber drawings, and coordinate system matching measurement.
CNC fixed coordinate system mode, can quickly and accurately batch measurement.
Product Parameters
CHT Series Automatic Image Measuring Instrument Technical Parameters
Product Model |
CHT322A |
CHT432A |
Travel Range |
|
|
X (mm) |
300 |
400 |
Y (mm) |
200 |
300 |
Z (mm) |
200 |
200 |
Main Structure |
Column type |
Column type |
Frame Material |
Marble |
Marble |
Monitor |
24 - inch LCD (1920×108) |
24 - inch LCD (1920×108) |
Image Sensor |
160w high - definition color industrial camera |
160w high - definition color industrial camera |
Raster Display Resolution |
0.5μm |
0.5μm |
Lens |
6.5X manual zoom |
6.5X manual zoom |
Magnification*1 |
Optical: 0.7X - 4.5X, Image: 32 - 206X |
Optical: 0.7X - 4.5X, Image: 32 - 206X |
Lighting System |
|
|
Transmitted Light |
LED telecentric transmitted lighting |
LED telecentric transmitted lighting |
Surface Light |
5 - ring 8 - zone segmentation lighting, 256 - level adjustable |
5 - ring 8 - zone segmentation lighting, 256 - level adjustable |
Detection Accuracy*2 |
|
|
X/Y axis |
(2.5 + L/200)μm |
(2.5 + L/200)μm |
X⊥Y |
(3.0 + L/200)μm |
(3.0 + L/200)μm |
Z axis*3 |
(5.0 + L/200)μm |
(5.0 + L/200)μm |
Maximum Speed |
|
|
XY (mm/s) |
500 |
500 |
Z (mm/s) |
100 |
100 |
Overall Dimensions (mm) |
760×1220×1670 |
860×1350×1670 |
Instrument Weight (kg) |
600 |
650 |
Load Capacity (kg) |
25 |
25 |
Power Supply |
1500W |
2000W |
Sensor Configuration*4 |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Motion Control |
Servo control system |
Servo control system |
Measurement Software |
VisionX |
VisionX |
Operating Voltage |
200 - 240VAC, 50/60Hz |
200 - 240VAC, 50/60Hz |
Working Environment |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
*1 Image magnification is an approximate value, and the specific value is related to the size and resolution of the monitor.
*2 At the focusing position, when the ambient temperature is 20°C±1°C and the load on the carrier table is less than 5kg, L is the movement amount of the carrier table (mm).
*3 Tested with the standard gauge under the ambient temperature of 20°C±1°C.
*4 Three height - measuring sensors are optional.
Product Model |
CHT322U |
CHT432U |
Travel Range |
|
|
X (mm) |
300 |
400 |
Y (mm) |
200 |
300 |
Z (mm) |
200 |
200 |
Main Structure |
Column type |
Column type |
Frame Material |
Marble |
Marble |
Monitor |
24 - inch LCD (1920×108) |
24 - inch LCD (1920×108) |
Image Sensor |
160w high - definition color industrial camera |
160w high - definition color industrial camera |
Raster Display Resolution |
0.1μm |
0.1μm |
Lens |
8.3X electric continuous zoom |
8.3X electric continuous zoom |
Magnification*1 |
Optical: 0.6 - 5.0X, Image: 27 - 229X |
Optical: 0.6 - 5.0X, Image: 27 - 229X |
Lighting System |
|
|
Transmitted Light |
LED telecentric transmitted lighting |
LED telecentric transmitted lighting |
Surface Light |
6 - ring 8 - zone segmentation lighting, 256 - level adjustable |
6 - ring 8 - zone segmentation lighting, 256 - level adjustable |
Coaxial Light |
Optional, LED light |
Optional, LED light |
Detection Accuracy*2 |
|
|
X/Y axis |
(2.0 + L/200)μm |
(2.0 + L/200)μm |
X⊥Y |
(3.0 + L/200)μm |
(3.0 + L/200)μm |
Z axis*3 |
(4.5 + L/200)μm |
(4.5 + L/200)μm |
Maximum Speed |
|
|
XY (mm/s) |
500 |
500 |
Z (mm/s) |
100 |
100 |
Overall Dimensions (mm) |
760×1220×1670 |
860×1350×1670 |
Instrument Weight (kg) |
600 |
650 |
Load Capacity (kg) |
25 |
25 |
Power Supply |
1500W |
2000W |
Sensor Configuration*4 |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Motion Control |
Servo control system |
Servo control system |
Measurement Software |
VisionX |
VisionX |
Operating Voltage |
200 - 240VAC, 50/60Hz |
200 - 240VAC, 50/60Hz |
Working Environment |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
*1 Image magnification is an approximate value, and the specific value is related to the size and resolution of the monitor.
*2 At the focusing position, when the ambient temperature is 20°C±1°C and the load on the carrier table is less than 5kg, L is the movement amount of the carrier table (mm).
*3 Tested with the standard gauge under the ambient temperature of 20°C±1°C.
*4 Three height - measuring sensors are optional.
Product Model |
CHT322S |
CHT432S |
Travel Range |
|
|
X (mm) |
300 |
400 |
Y (mm) |
200 |
300 |
Z (mm) |
200 |
200 |
Main Structure |
Column type |
Column type |
Frame Material |
Marble |
Marble |
Image Sensor |
500w high - definition color industrial camera |
500w high - definition color industrial camera |
Monitor |
24 - inch LCD (1920×108) |
24 - inch LCD (1920×108) |
Raster Display Resolution |
0.1μm |
0.1μm |
Lens |
13.3X electric continuous zoom |
13.3X electric continuous zoom |
Magnification*1 |
Optical: 0.6 - 8.0X, Image: 17 - 380X |
Optical: 0.6 - 8.0X, Image: 17 - 380X |
Lighting System |
|
|
Transmitted Light |
LED telecentric transmitted lighting |
LED telecentric transmitted lighting |
Surface Light |
6 - ring 8 - zone segmentation lighting (white light); Optional, replaceable RGB light source |
6 - ring 8 - zone segmentation lighting (white light); Optional, replaceable RGB light source |
Coaxial Light |
LED light |
LED light |
Detection Accuracy*2 |
|
|
X/Y axis |
(1.8 + L/250)μm |
(1.8 + L/250)μm |
X⊥Y |
(2.2 + L/250)μm |
(2.2 + L/250)μm |
Z axis*3 |
(3.0 + L/200)μm |
(3.0 + L/200)μm |
3D Scanning Imaging Measurement*4 |
|
|
Z - direction measurement range*5 |
5mm |
5mm |
Scanning width*6 |
30mm |
30mm |
Repeatability*7 |
±1μm |
±1μm |
Measurement accuracy*7 |
±0.1%F.S. |
±0.1%F.S. |
Scanning speed*8 |
10 - 80mm/s |
10 - 80mm/s |
Support fly - shot measurement mode |
Support |
Support |
Support navigation camera |
Support |
Support |
Sensor configuration*9 |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Maximum Speed |
|
|
XY (mm/s) |
500 |
500 |
Z (mm/s) |
100 |
100 |
Overall Dimensions (mm) |
760×1220×1670 |
860×1350×1670 |
Instrument Weight (kg) |
600 |
650 |
Load Capacity (kg) |
25 |
25 |
Power Supply |
1500W |
2000W |
Motion Control |
Servo control system |
Servo control system |
Measurement Software |
VisionX |
VisionX |
Operating Voltage |
200 - 240VAC, 50/60Hz |
200 - 240VAC, 50/60Hz |
Working Environment |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
Product Model |
CHT452 |
CHT562 |
CHT682 |
Travel Range |
|
|
|
X (mm) |
400 |
500 |
600 |
Y (mm) |
500 |
600 |
800 |
Z (mm) |
200 |
200 |
200 |
Main Structure |
Gantry type |
Gantry type |
Gantry type |
Frame Material |
Marble |
Marble |
Marble |
Monitor |
24 - inch LCD (1920×108) |
24 - inch LCD (1920×108) |
24 - inch LCD (1920×108) |
Image Sensor |
160w high - definition color industrial camera |
160w high - definition color industrial camera |
160w high - definition color industrial camera |
Raster Display Resolution |
0.1μm |
0.1μm |
0.1μm |
Lens |
8.3X electric continuous zoom |
8.3X electric continuous zoom |
8.3X electric continuous zoom |
Magnification*1 |
Optical: 0.6 - 5.0X, Image: 27 - 229X |
Optical: 0.6 - 5.0X, Image: 27 - 229X |
Optical: 0.6 - 5.0X, Image: 27 - 229X |
Lighting System |
|
|
|
Transmitted Light |
LED telecentric transmitted lighting |
LED telecentric transmitted lighting |
LED telecentric transmitted lighting |
Surface Light |
6 - ring 8 - zone segmentation lighting, 0 - 255 - level adjustable |
6 - ring 8 - zone segmentation lighting, 0 - 255 - level adjustable |
6 - ring 8 - zone segmentation lighting, 0 - 255 - level adjustable |
Coaxial Light |
Optional, LED light |
Optional, LED light |
Optional, LED light |
Detection Accuracy*2 |
|
|
|
X/Y axis |
(2.5 + L/200)μm |
(2.5 + L/200)μm |
(2.5 + L/200)μm |
X⊥Y |
(3.0 + L/200)μm |
(3.0 + L/200)μm |
(3.0 + L/200)μm |
Z axis*3 |
(4.5 + L/200)μm |
(4.5 + L/200)μm |
(4.5 + L/200)μm |
Maximum Speed |
|
|
|
XY (mm/s) |
500 |
500 |
500 |
Z (mm/s) |
100 |
100 |
100 |
Overall Dimensions (mm) |
950×1320×1700 |
1100×1600×1700 |
1200×2000×1700 |
Instrument Weight (kg) |
1400 |
1500 |
2000 |
Load Capacity (kg) |
25 |
25 |
25 |
Power Supply |
2000W |
2500W |
2500W |
Sensor configuration*4 |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Optional, (1) contact probe; (2) white - light confocal; (3) triangular laser |
Motion Control |
Servo control system |
Servo control system |
Servo control system |
Measurement Software |
VisionX |
VisionX |
VisionX |
Operating Voltage |
200 - 240VAC, 50/60Hz |
200 - 240VAC, 50/60Hz |
200 - 240VAC, 50/60Hz |
Working Environment |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
*1 Image magnification is an approximate value, and the specific value is related to the size and resolution of the monitor.
*2 At the focusing position, when the ambient temperature is 20°C±1°C and the load on the carrier table is less than 5kg, L is the movement amount of the carrier table (mm).
*3 Tested with the standard gauge under the ambient temperature of 20°C±1°C.
*4 Three height - measuring sensors are optional.
Product Model |
CHT0810 |
CHT1012 |
CHT1215 |
Travel Range |
|
|
|
X (mm) |
800 |
1000 |
1200 |
Y (mm) |
1000 |
1200 |
1500 |
Z (mm) |
200 |
200 |
200 |
Main Structure |
Gantry type |
Gantry type |
Gantry type |
Frame Material |
Marble |
Marble |
Marble |
Monitor |
24 - inch LCD (1920×108) |
24 - inch LCD (1920×108) |
24 - inch LCD (1920×108) |
Image Sensor |
160w high - definition color industrial camera |
160w high - definition color industrial camera |
160w high - definition color industrial camera |
Raster Display Resolution |
0.1μm |
0.1μm |
0.1μm |
Lens |
8.3X electric continuous zoom (Optional 13.3X electric continuous zoom lens) |
8.3X electric continuous zoom (Optional 13.3X electric continuous zoom lens) |
8.3X electric continuous zoom (Optional 13.3X electric continuous zoom lens) |
Magnification*1 |
Optical: 0.6 - 5.0X, Image: 27 - 229X |
Optical: 0.6 - 5.0X, Image: 27 - 229X |
Optical: 0.6 - 5.0X, Image: 27 - 229X |
Lighting System |
|
|
|
Transmitted Light |
LED telecentric transmitted lighting |
LED telecentric transmitted lighting |
LED telecentric transmitted lighting |
Surface Light |
6 - ring 8 - zone segmentation lighting, 0 - 255 - level adjustable |
6 - ring 8 - zone segmentation lighting, 0 - 255 - level adjustable |
6 - ring 8 - zone segmentation lighting, 0 - 255 - level adjustable |
Coaxial Light |
Optional, LED light |
Optional, LED light |
Optional, LED light |
Detection Accuracy*2 |
|
|
|
X/Y axis |
(3.0 + L/200)μm |
(3.5 + L/200)μm |
(3.5 + L/200)μm |
X⊥Y |
(4.0 + L/200)μm |
(4.5 + L/200)μm |
(4.5 + L/200)μm |
Z axis*3 |
(4.5 + L/200)μm |
(4.5 + L/200)μm |
(4.5 + L/200)μm |
Maximum Speed |
|
|
|
XY (mm/s) |
500 |
500 |
500 |
Z (mm/s) |
100 |
100 |
100 |
Overall Dimensions (mm) |
1750×2220×1700 |
2150×2620×1700 |
2550×3220×1700 |
Instrument Weight (kg) |
2900 |
3600 |
4500 |
Load Capacity (kg) |
50 |
50 |
50 |
Power Supply |
2500W |
2500W |
2500W |
Sensor configuration*4 |
Optional: (1) contact probe; (2) white - light confocal; (3) triangular laser |
Optional: (1) contact probe; (2) white - light confocal; (3) triangular laser |
Optional: (1) contact probe; (2) white - light confocal; (3) triangular laser |
Motion Control |
Servo control system |
Servo control system |
Servo control system |
Measurement Software |
VisionX |
VisionX |
VisionX |
Operating Voltage |
200 - 240VAC, 50/60Hz |
200 - 240VAC, 50/60Hz |
200 - 240VAC, 50/60Hz |
Working Environment |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
Temperature 20°C±2°C, humidity 20 - 80%, vibration <0.002g, below 15HZ |
*1 Image magnification is an approximate value, and the specific value is related to the size and resolution of the monitor.
*2 At the focusing position, when the ambient temperature is 20°C±1°C and the load on the carrier table is less than 5kg, L is the movement amount of the carrier table (mm).
*3 Tested with the standard gauge under the ambient temperature of 20°C±1°C.
*4 Three height - measuring sensors are optional.
Certifications
Packaging & Shipping